ROFU® MAGNETIC DOOR LOCKING DEVICE
MODEL 8011-LC FOR SINGLE DOOR
![]()
![]()
|
STANDARD FEATURES |
|
| Holding Force: | 1500 lbs. |
| Easy Installation: - |
Versatile mounting brackets for new and existing doors and frames. |
| Fail Safe: - |
Releases instantly when power is disconnected. No residual magnetism. |
| Fail Alarm: | May be released upon activation of fire alarm. |
| Housing: | Attractive, heavy duty, anodized extruded aluminum |
| Voltage: | 12VDC or 24VDC (Field Adjustable) |
| Current Draw: - |
450 mA at 12 VDC 225 mA at 24 VDC |
| Mounting hardware included with unit. | |
| Limited Lifetime Warranty | |
|
SPECIFICATIONS |
|
| Magnet Size: | 10-1/2" x 2-5/8" x 1-5/8" (LxHxW) |
| Armature Size: | 7-1/4" x 2-3/8" x 5/8" (LxHxW) |
| Finishes: | US28 - Aluminum or
US40 - Brown US3 also available, Call for Quote and availability |
|
OPTIONAL FEATURES |
|
| Time Delay -TD |
A timing chip is added to the PC Board and a 0-30 second adjustable switch can be set with a screwdriver to get the desired "door open" time. Specify 8011-LC-TD. |
|
OPTIONAL ACCESSORIES |
|
| Accessories: | Filler Plates, L-Brackets, Glass door mounting aids, Z-Brackets for in-swinging doors, #21031 Angle Brackets & Spacers. |
|
TYPICAL INSTALLATION ROFU® MODEL 8011-LC |
|||||
|
|
|||||
|
Out Swinging door |
Inswinging door |
||||
|
|
|||||
|
|
|||||
|
Switch or solid state switching device |
Important: The local on\off switch must be |
Switch or solid state |
|
|
||
|
Note: Not to scale. Technical Data are subject to change
without notice. |
||