Photo of Bosch DS150i     Bosch logo     BOSCH DS150i Info

Bosch DS150i

The DS150i Series Exit Sensors are Passive Infrared Detectors specifically designed for “request to-exit” applications. They detect motion in their coverage area andsignal an access control system ordoor control device.

FEATURES:
• Single or Double Door Use
• Wall and Ceiling Mountable
• Internal Vertical Pointability
• Wrap-Around Coverage Pattern
• 12 or 24 AC or DC Operation
• Up to 60 Second Adjustable Latch Time
• Selectable Relay Trigger Mode
• Selectable Fail Safe/Fail Secure
• UL Listed
• CE Approved

SPECIFICATIONS:

POWER REQUIREMENTS 12 or 24 VAC or VDC, 26 mA @ 12 VDC     

RELAY OUTPUT Two Form “C” Contacts                                      

RELAY LATCH TIME Adjustable to 60 seconds                              

RELAY MODE Programmable retrigger or non-retrigger mode        

POWER LOSS DEFAULT Programmable Fail Safe or Fail Secure modes

STORAGE & OPERATING TEMPERATURE -20° to +120°F / -29° to +50°C

TEST FEATURES Externally visible activation LED                             

DIMENSIONS 1.5" H., by 6.25" W., by 1.5" D. / 3.8 cm H., 15.8 cm W., 3.8cm                                                        

COVERAGE 8 ft. by 10 ft. / 2.4 m by 3 m

MOUNTING Surface Mount      

PATTERN POINTABILITY ±14° Vertical

RADIO FREQUENCY INTERFERENCE(RFI) IMMUNITY No alarm or setup on critical frequencies in the range from 26 to 1000 Megahertz at 50 v/m.                        

LISTING UL Listing BP6245 

 

Photo of Bosch DS160     Bosch logo     BOSCH DS160 Info

Bosch DS160

 

Bosch - DS160 High Performance Request-to-exit Detector ( Grey)

Introduction

The DS160 Series consists of the DS160 Detector (light gray) and the DS161 Detector (black) specifically designed for Request-to-exit (REX) applications. With features such as timers, door monitor with sounder alert, and pointable coverage, the DS160 and DS161 have the flexibility to meet the most stringent REX requirements. The exclusive Sequential Logic Input (SLI) provides added security that is not offered in any other REX device.

Features:

  • Door monitor with sounder alert
  • Sequential Logic Input (SLI)
  • Internal vertical pointability
  • Wrap-around coverage pattern with precise pattern control
  • Up to 64 second adjustable latch time
  • Selectable relay trigger mode
  • Selectable fail‑safe or fail‑secure modes
  • Adjustable sounder volume
  • Activation LED

    Functions

    Sequential Logic Input (SLI)

    The SLI terminal allows connection of a second device to require sequential detection. This eliminates the possibility that an object that is slid through the door or underneath the door will activate the detector. This input can also be used to lock the sensor if motion is present outside the premises.

    Door Monitor

    The sensor can monitor a door contact to allow special control of the internal relay. For example, if the door is opened within the relay time period, the sensor can be programmed to halt the timer. If the door is not opened within a specific time period, the relay can be programmed to deactivate.

    Sounder Alert

    An integrated sounder can be programmed to activate if the door is left open too long. The sounder volume is fully adjustable to 85 dB.

    Keycard Input

    The keycard input allows the sensor relay to be controlled from an external source, such as an access control system or card reader.

    Certifications and Approvals

    UL Standard UL294, Access Control System Units

    Installation/Configuration Notes

    The coverage (detection area) varies depending on the mounting height above the floor, angle of the lens, and whether the unit is mounted on a wall above the door or on the ceiling. The coverage is 2.4 m x 3 m (8 ft x 10 ft) The coverage patterns for the detector at a height of 2.3 m (7.5 ft) are shown. The coverage pattern increases or decreases with height and detector alignment.

    Note: When you mount the unit on the wall and the lens points straight down, some detection zones point toward the wall and do not detect movement.

    Shown here are views of the coverage pattern with the detector mounted at 2.3 m (7.5 ft) above the floor with the lens pointed straight down. Zones that are pointed toward the wall are not shown.

    Technical Specifications

    Alarm Output: Two Form C relay contacts each rated 1 A at 30 VAC or VDC for resistive loads
    Indicators: 1 activation LED
    Radio Frequency Interference (RFI) Immunity: No alarm or setup on critical frequencies in the range from 26 MHz to 1000 MHz at 50 V/m Relay Latch Time: Adjustable from 0.5 sec to 64 sec.

    Enclosure Design

    Dimensions: 4.5 cm x 17.1 cm x 4.4 cm (1.80 in. x 6.75 in. x 1.75 in.) Material: High impact ABS plastic enclosure

    Environmental Considerations

    Operating Temperature: -29°C to +49°C (-20°F to +120°F)For UL
    Certificated installations, 0°C to +49°C (+32°F to +120°F)

    Modes

    Power Loss Default: Programmable fail-safe or fail-secure modes. Timer: Programmable reset accumulative or non-reset counting mode.

    Mounting

    Location: Surface mount

    Power Requirements

    Current Draw: 8 mA nominal standby current, 39 mA at 12 VDC in alarm
    Voltage: 12 VAC or VDC to 30 VAC or VDC